Deye SUN-3.6/5/6/7/7.6/8/10K-SG05LP1-EU
Single Phase Hybrid Inverter | 3.6-10kW | | 2 MPPT | LV Battery Supported
- Colorful touch LCD, IP65 protection degree
- AC couple to retrofit existing solar system
- Max. 16 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
- Max. charging/discharging current of 190A
- 6 time periods for battery charging/discharging
- Support storing energy from diesel generator
Deye SUN-3.6/5/6/7/7.6/8/10K-SG05LP1-EU — Single Phase Hybrid Inverter | 3.6-10kW | | 2 MPPT | LV Battery Supported. Original equipment with factory warranty from the official Deye distributor in Belarus. Delivery across Belarus and Russia.
Request Price
Documentation
Technical Specifications
| Model | SUN-3.6K-SG05LP1-EU | SUN-5K-SG05LP1-EU | SUN-6K-SG05LP1-EU | SUN-7K-SG05LP1-EU | SUN-7.6K-SG05LP1-EU | SUN-8K-SG05LP1-EU | SUN-10K-SG05LP1-EU |
| Battery Input Data | |||||||
| Battery Type | Lead-acid or Lithium-ion | ||||||
| Battery Voltage Range(V) | 40-60 | ||||||
| Max.Charging Current(A) | 90 | 120 | 135 | 175 | 190 | 190 | 210 |
| Max.Discharging Current(A) | 90 | 120 | 135 | 175 | 190 | 190 | 210 |
| Charging Strategy for Li-ion Battery | Self-adaption to BMS | ||||||
| Number of battery input | 1 | ||||||
| PV String Input Data | |||||||
| Max. PV Access Power (W) | 7200 | 10000 | 12000 | 14000 | 15200 | 16000 | 20000 |
| Max PV Input Power(W) | 5760 | 8000 | 9600 | 11200 | 12160 | 12800 | 16000 |
| Max PV Input Voltage(V) | 500 | ||||||
| Start-up Voltage(V) | 125 | ||||||
| MPPT Voltage Range(V) | 150-425 | ||||||
| Rated PV Input Voltage(V) | 370 | ||||||
| Max Operating PV Input Current(A) | 13+13 | 26+26 | |||||
| Max Input Short-Circuit Current(A) | 17+17 | 34+34 | |||||
| No.of MPP Trackers/No.of String Per MPP Tracker | 2/1+1 | 2/2+2 | |||||
| AC Input/Output Data | |||||||
| Rated AC Input/Output Active Power(W) | 3600 | 5000 | 6000 | 7000 | 7600 | 8000 | 10000 |
| Max AC Input/Output Apparent Power (VA) | 3960 | 5500 | 6600 | 7700 | 8360 | 8800 | 11000 |
| Rated AC Input/Output Current(A) | 16.4/15.7 | 22.7/21.7 | 27.3/26.1 | 31.9/30.5 | 34.5/33 | 36.4/34.8 | 45.5/43.5 |
| Max AC Input/Output Current(A) | 18/17.2 | 25/23.9 | 30/28.7 | 35.0/33.5 | 38/36.3 | 40/38.3 | 50/47.9 |
| Max Continuous AC Passthrough (grid to load)(A) | 35 | 40 | 50 | ||||
| Peak Power (off-grid)(W) | 2 times of rated power,10s | ||||||
| Rated Input/Output Voltage/Range(V) | 220V/230 0.85Un-1.1Un | ||||||
| Grid Connection Form | L+N+PE | ||||||
| Rated Input/Output Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz | ||||||
| Power Factor Adjustment Range | 0.8 leading-0.8lagging | ||||||
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||||||
| DC Injection Current | <0.5%ln | ||||||
| Efficiency | |||||||
| Max Efficiency | 97.60% | ||||||
| Euro Efficiency | 96.50% | ||||||
| MPPT Efficiency | >99% | ||||||
| Equipment Protection | |||||||
| Integrated | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | ||||||
| Surge Protection Level | TYPE II(DC),TYPE II(AC) | ||||||
| Interface | |||||||
| Communication Interface | WIFI/RS485/CAN | ||||||
| LCD/LED Display | LCD | ||||||
| General Data | |||||||
| Operating Temperature Range | -40 to +60℃, >45℃ Derating | ||||||
| Permissible Ambient Humidity | 0~100% | ||||||
| Permissible Altitude | 2000m | ||||||
| Noise | <45 | ||||||
| Ingress Protection(IP) Rating | IP 65 | ||||||
| Inverter Topology | Non-Isolated | ||||||
| Over Voltage Category | OVC II(DC),OVC III(AC) | ||||||
| Cabinet size(W*H*D)[mm] | 330×580×232 (Excluding Connectors and Brackets) | ||||||
| Weight[kg] | 24.9 | ||||||
| Warranty | 5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | ||||||
| Type Of Cooling | Intelligent air cooling | ||||||
| Grid Regulation | IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105 | ||||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||||||
FAQ
How much does Deye SUN-3.6/5/6/7/7.6/8/10K-SG05LP1-EU cost?
The price depends on order volume. Send a request or call +375 (33) 626-70-51 — we will send the current price list within one business day.
Is this original Deye equipment?
Yes, we are the official Deye distributor in Belarus. All equipment is supplied directly from the factory with registered serial numbers and factory warranty.
Do you deliver to Belarus and Russia?
Yes, we deliver across Belarus (1–3 days) and Russia (3–7 days). Pickup from the Minsk warehouse is available.
Related Products

SUN-12/14/16/18K-SG01LP1-EU-AM3-P
Single Phase Hybrid Inverter | 12-18kW | 3 MPPT | LV Battery Supported

SUN-12/14/16K-SG01LP1-EU
Single Phase Hybrid Inverter | 12-16kW | 3 MPPT | LV Battery Supported

SUN-3/3.6/4/4.6/5/6K-SG06LP1-EU-BM1/BM2
Single Phase Hybrid Inverter | 3-6kW | 2 MPPT | LV Battery Supported

SUN-3/3.6/4/4.6/5/6K-SG06LP1-EU-CM1/CM2